Extron Electronics VN-Matrix 200 Series User Manual
Page 95
Alarm Type Description - Decoder
Alarm Type
Description
Action
Default settings
Decoder Alarm
No decoder video
data
Indicates that there is a valid
connection, no video data
present. Usually accompanied by
“no source data stream” message
in the web interface.
Warning, reporting
No decoder mode
No matching decoder mode for
the incoming stream.
Warning, reporting
No source report
Unable to detect the format of
the received data stream.
Warning, reporting
Recovered audio
Warning, reporting
No decoder audio
data
Warning, reporting
Bad audio at decoder
Warning, reporting
Bad audio PLL
Warning, reporting
Video network
packets dropped
Excessive network packet loss has
occurred.
Warning, reporting
Decoder buffer
overflow
The incoming data rate is high;
reduce the pipeline delay.
Warning, reporting
Decoder buffer
underflow
The incoming data rate is too low;
increase the pipeline delay.
Warning, reporting
Bad video PLL
The decoder cannot synchronize
to the video data.
Warning, reporting
No decoder ANC data The decoder is not receiving any
embedded audio (ancillary) data.
Warning, reporting
Missing ANC at
decoder
The Decoder is receiving poor
quality ANC data.
Warning, reporting
Recovered ANC
Error correction has recovered
corrupted / missing ANC.
Warning, reporting
Alarm Type description - Controller
Alarm Type
Description
Action
Default Settings
Contr
oller
Alarm
Bad device
The controller is unable to contact
the specified device. The device is
not available or has failed.
Note that this alarm is only
generated on the controller.
Check the device in
question.
Is power applied?
Is the network cable /
connection present?
Has the unit been
removed?
Critical, reporting
VN-Matrix 200 Series • Alarms and SNMP
90