Alarm Type Description - Decoder

Alarm Type

Description

Action

Default settings

Decoder Alarm

No decoder video
data

Indicates that there is a valid
connection, no video data
present. Usually accompanied by
“no source data stream” message
in the web interface.

Warning, reporting

No decoder mode

No matching decoder mode for
the incoming stream.

Warning, reporting

No source report

Unable to detect the format of
the received data stream.

Warning, reporting

Recovered audio

Warning, reporting

No decoder audio
data

Warning, reporting

Bad audio at decoder

Warning, reporting

Bad audio PLL

Warning, reporting

Video network
packets dropped

Excessive network packet loss has
occurred.

Warning, reporting

Decoder buffer
overflow

The incoming data rate is high;
reduce the pipeline delay.

Warning, reporting

Decoder buffer
underflow

The incoming data rate is too low;
increase the pipeline delay.

Warning, reporting

Bad video PLL

The decoder cannot synchronize
to the video data.

Warning, reporting

No decoder ANC data The decoder is not receiving any

embedded audio (ancillary) data.

Warning, reporting

Missing ANC at
decoder

The Decoder is receiving poor
quality ANC data.

Warning, reporting

Recovered ANC

Error correction has recovered
corrupted / missing ANC.

Warning, reporting

Alarm Type description - Controller

Alarm Type

Description

Action

Default Settings

Contr

oller

Alarm

Bad device

The controller is unable to contact
the specified device. The device is
not available or has failed.
Note that this alarm is only
generated on the controller.

Check the device in
question.
Is power applied?
Is the network cable /
connection present?
Has the unit been
removed?

Critical, reporting