Extron Electronics VN-Matrix 200 Series User Manual
Page 46
Is the target display completely blank
?
START
YES
NO
Check the POWER indicator on the VN
-MATRIX Decoder
...
UNLIT
LI
T
FLASHING
What’s the problem
?
Check the STATUS indicator
on the Encoder
...
UNLIT
FLASHING
NO POWE
R
Check the PSU connection to the VN-MATRIX Decoder
.
Check for ‘green’ light on the PSU
.
Check mains cabl
e,
fuse and supply
.
POWER/THERMAL FAUL
T
The unit has shut down due to either a power supply fault or over temperature condition
.
Check for obstructed ventilation grilles,
excessive ambient
temperatur
e.
Cycle the power off and on to reset the uni
t.
If the problem recurs and ambient temperature is within limit
s,
try
using
a different PSU
.
NO SOURCE SELECTE
D,
ENCODER
OFFLINE (Nodata Splash disabled
)
SOURCE DATASTREAM BEING RECEIVED
Check that the source is not outputting a ‘blank’ signal
.
Check that the display is powered and not in standby mode
.
Check for loos
e/
incorrect
connections or faulty cables between the Decoder and the displa
y.
If the display has multiple inputs
,
check that the correct input is
selected
.
If there are setup options for the display input
, check that these are
appropriate for the Decoder output format
.
Check that the display is compatible
with the Decoder output forma
t.
Message Displayed… “No Source Datastream
”
Source image is stable
but has a color cast
Source image is unstable or corrupted
Displayed image is
frozen
.
Check that the Decoder has a source selected
.
Check that the Decoder is not in disabled or standby mode.
Check that the corresponding Encoder device is operating and set up
correctly by following the Source Checkup.
Check for networ
k/
communication problems
.
Check for loos
e/
incorrect connections or faulty cables between the source
and the Encode
r.
Check that the visual disruption is not on the original source signal
.
Check to see if the Encoder local monitor has the same color cast
.
If so, check that the correct color space has been applied to the source.
Check for loos
e/
incorrect connections or faulty cables between the Decoder
and the displa
y.
Check that the original source itself is not frozen
.
If the source is OK
, the likely cause is that the source datastream has been
interrupted and the Nodata Splash option is disabled
. This will result in the
Decoder displaying the last valid source frame received
. Follow the checks
above for “No Source Datastream
”.
Message Displayed… “No Matching Output
Mode
”
The Decoder is receiving a data stream but is unable to find an output mode that matches the source forma
t. Most likely cause is that the Encoder is
using a custom input mode for which there is no matching output mode on the Decoder
. If this is the case you will need to create a custom output mode.
Image is stable but ‘drops
out’ (goes blac
k)
or
freezes intermittently
Check that the visual disruption is not on the original source signal
.
The image disruption could be caused by data packets being lost
. There
may be insufficient network bandwidth available resulting from high network
traffic or poor network performance
. Try increasing the compression settings
or adjusting the bandwidth limitation settings on the Encoder.
Displayed image is
noticeably poorer quality than the source
, either in
terms of clarity or refresh rate
.
The compressio
n/
bandwidth limitation settings on the Encoder may be set
too high
. Try decreasing the compression settings or adjusting the
bandwidth limitation settings on the Encoder.
VN-Matrix 200 Series • System Configuration
41