beautypg.com

Extron Electronics VN-Matrix 200 Series User Manual

Page 34

background image

Figure 20.

Configure Page

f

Check that the

Input Mode

is set to auto. if not, see “

Input Mode

”.

g

Check that the

Current Mode

shows the format of the connected source. If it does

not, see “

Input Mode

”.

h

Check the

Multicast Enable

box if RTP multicast source streaming is required,

otherwise ensure this box is unchecked to enable RTP unicast.

TIP: If your source or local monitor uses EDID, you may need to look at these

settings, see “

EDID options

” and

é

in the previous diagram.

i

Does the source have an audio channel?

No...

Yes...

Encoder setup is complete, click the

Save All

tab.

If a local monitor is connected it should now be
displaying the source. If it is not, see “

Source

Checkup

.”

See “

Additional Setup for

Audio

”.

j

Repeat this procedure (from step a) for each encoder in the system. To configure the

VNC 200 device as a decoder (display), see “

Configuring a VNC 200 as a Decoder

(Display)

.”

VN-Matrix 200 Series • System Configuration

29