Extron Electronics VN-Matrix 200 Series User Manual
Page 111
Digital Audio I/O (SPDIF In and Out/Loop)
Function:
Input and Output/Loop-Through for digital audio
Connector Type:
RCA Phono Socket
Mating Connector:
RCA Screened Phono Plug
Recommended Cable:
75W coaxial
Max. Cable Length:
10 meters (32 feet)
DVI Input (IN)
Function:
Digital or analog video input for encoding.
Connector Type:
DVI-I (female).
Pin-out Details:
Close-up view of Dual Link female DVI-I input
1
9
8
17
24 C3 C4
C1 C2
C5
Digital Connections
Pin Function
Pin
Function
Pin
Function
1
TMDS 2-
9
TMDS 1-
17
TMDS 0-
2
TMDS 2+
10
TMDS 1+
18
TMDS 0+
3
Ground (2/4)
11
Ground (1/3)
19
Ground (0/5)
4
nc
12
nc
20
nc
5
nc
13
nc
21
nc
6
DDC Clock
14
+5 V supply*
22
Ground (Clock)
7
DDC Data
15
Ground (for 5 V)
23
TMDS Clock+
8
Analog V-Sync
16
Hot Plug Detect
24
TMDS Clock-
NOTE: 5 V supply is provided by VN 200 and limited by 200 mA polyswitch.
All ground pins are linked internally.
Analog Connections
Pin Function
C1
Red signal
C2
Green signal
C3
Blue signal
C4
Horizontal sync
C5
Ground
Mating Connector:
DVI-D or DVI-I (male)
VN-Matrix 200 Series • Technical Data