Extron Electronics VN-Matrix 200 Series User Manual
Page 82
2.
Select the
Device
tab.
3.
Click on the
display0
link in the Configuration region.
4.
Use the
Output Format
drop-down list to select the mode you created in the
previous section.
5.
Select
Update
. The source should now be displayed correctly on the decoder output.
The mode must now be modified so that it can be detected automatically when the source
is connected to the encoder.
To do this, you will:
1.
Retrieve timing information using a telnet session.
2.
Enter the observed timing values in the VN-Matrix web GUI.
Opening a telnet session on port 4002 with a VN-Matrix decoder
To open a telnet session with the VN-MATRIX decoder, perform the following procedure:
1.
From the Windows taskbar, open a terminal window and then type
telnet xxx.
xxx.xxx.xxx 4002
where
xxx.xxx.xxx.xxx
represents the IP address of the
VN-Matrix decoder. Then, press
Source information will now continually be streamed to the telnet window. Although
the numeric values may be different, you will see a line similar to the one shown
below:
resolution update message: 1280,960,60,1000,1800,fbbd,108001440,1:
The first five numeric values are interpreted as:
Parameter
Meaning
1280
Active area width of current source (in pixels)
960
Active area height of current source (in pixels)
60
Frame rate of current source, in Hz
1000
Total line count of current source
1800
Total pixels per line of current source
2.
Write down the values that are reported for:
•
Active area width
•
Active area height
•
Frame rate
•
Total line count
•
Total pixels
These values will be required in the next section.
VN-Matrix 200 Series • Advanced Setup Procedures