Extron Electronics VN-Matrix 200 Series User Manual
Page 117
Serial Port Login Procedure
1.
From the Login: prompt, type
config
followed by the
2.
When prompted for a password, type
config
followed by the
The following menu will then appear.
Network Port 1
Network Port 2
==============
==============
0.
Speed/Duplex: auto_10_100_1000
10. Speed/Duplex: auto_10_100_1000
1. Boot method: static [dhcp]
11. Boot method: static [dhcp]
2. address: 192.168.0.1
12. address: 192.168.1.1
3. netmask: 255.255.255.0
13. netmask: 255.255.255.0
4.
gateway: 192.168.0.1
14
Gateway: 192.168.0.1
5. broadcast:
15. broadcast:
6.
mtu: 1500
16. mtu: 1500
7. controller ip: 192.168.0.18
17. ip forwarding: 0
8. controller port: 5432
18. webserver port: 80
9. Exit
3.
Type the menu option number required followed by the
4.
Where required, type the new value followed by the
5.
To exit the menu and return to the main command prompt, type
9
followed by the
Command options
The following commands are also supported from the main command prompt:
Exit
To logout from the session
Reboot
To force the VN 200 device to restart
Ping
To test network communications with another device (see
“
Understanding Network Performance
”)
VN-Matrix 200 Series • Technical Data