beautypg.com

Serial / telnet commands – Extron Electronics VN-Matrix 200 Series User Manual

Page 52

background image

3.

The Serial Port Control options are shown below.

4.

Using the

mode

drop-down menu select the client option (note that this will reveal the

destination box).

5.

Using the

destination

drop-down menu select

passthrough

for the appropriate

server.

6.

Change the other settings as required, then click the Save All tab.

Serial / Telnet Commands

The following commands can be used to provide basic remote control of a VN 200 system.
Commands can be issued either as part of a serial remote control configuration or by
using a Telnet application via the network.
In either case, a control session must first be initiated by sending a valid username and
password.
All commands must be terminated with a new line character (carriage return not required).
In programs such as Telnet, this is accomplished by pressing the Enter key.

Control Session Commands

user

Initiates a user login. To be able to change system settings you must login using the
“admin” user account.
Example:

user admin

pass

Specifies the password for the user account. By default this will be ‘admin’ but may have
been changed using the web interface (see “

Changing User Login Passwords

”).

Example:

pass admin

exit

Terminates the current remote control session.

VN-Matrix 200 Series • Serial Transport and Control Methodsl

47

This manual is related to the following products: