Sis programming and control, cont’d – Extron Electronics IPI 200 Series User Guide User Manual
Page 68
SIS Programming and Control, cont’d
IPI 100 and IPI 200 Series • SIS Programming and Control
B-10
Command
ASCII (Telnet)
(host to intercom)
URL Encoded
(host to intercom)
Response
(intercom to host)
Additional Description
Request the
model name
1I
1I
IPI 201
]
or
IPI 204
]
Request
the model
description
2I
2I
One‑Button IP
Intercom
]
or
Four‑Button IP
Intercom
]
Request
system
memory usage
3I
3I
Show amount of memory used and
total available memory for system
operations.
Request user
memory usage
4I
4I
Show amount of user memory used
and total available user memory.
Query IPI
module
32I
32I
IPI201
]
or
IPI204
]
201 = IPI 201 AAP or 2‑gang
204 = IPI 204 AAP or 2‑gang.
IP setup commands
Set the unit
name
24
E X1@
CN
}
W
X1@
CN
|
Ipn•
X1@ ]
Change the IPI’s name to one of
your choosing (
X1@
), such as “exec‑
boardroom‑ctrl”. The name consists
of up to 24 alphanumeric characters
(and the minus sign). The first
character must be a letter, the last
character cannot be a minus sign
(hyphen). Case does not matter.
Set unit name
to factory
default
24
E
•CN
}
W%20CN
|
Ipn•
X4( ]
X4(
= the factory default name,
which is a combination of the model
name and the last 3 pairs of hex
numbers in the controller’s MAC
address (e.g., IPI‑104‑IP‑00‑ 02‑3D).
Read the unit
name
E
CN
}
WCN
|
X1@ ]
or
X4( ]
X1@
= user‑defined name.
X4(
= factory default name.
Set date/
time
24
E X1#
CT
}
W
X1#
CT
|
Ipt•
X1# ]
X1#
= Local date and time in the
format: MM/DD/YY-HH:MM:SS.
Example: 09/07/06-10:54:00
.
Read date/
time
E
CT
}
W CT
|
X1# ]
Set GMT
offset
24
E X#
CZ
}
W
X#
CZ
|
Ipz
X# ]
X#
= Greenwich Mean Time (GMT)
offset value (‑12.00 to +14.00)
represents the difference in hours
and minutes relative to Greenwich,
UK. The leading zero is optional.
Do not use a plus (+) sign.
Read GMT
offset
E
CZ
}
WCZ
|
X#
]
Set daylight
saving time
24
E X3$
CX
}
W
X3$
CX
|
Ipx
X3$
]
X3$
=
Daylight saving time
0
= Daylight Saving Time off/ignore
1
= Daylight Saving Time on (USA/Canada)
2
= Daylight Saving Time on (Europe)
3
= Daylight Saving Time on (Brazil)