B-3

IPI 100 and IPI 200 Series • SIS Programming and Control

• If the IPI is on, it sends the boot and copyright messages when you first open

a Telnet connection to the IPI. You can see the day of the week, date, and time

if the IPI is connected via Telnet, but not via RS‑232. If you are using a Telnet

connection, the copyright message, date, and time are followed by a password

prompt.

Additional messages may be sent by the IPI in response to front panel selections

and volume adjustments and when scripts are executed during scheduled events.

Password information

The “

]

Password:” prompt requires a password (administrator level or user level)

followed by a carriage return. The prompt is repeated if the correct password is not

entered.
If the correct password is entered, the unit responds with “

]

Login Administrator

]

or “

]

Login User

]

”, depending on the password entered. If passwords are the same

for both administrator and user, the unit will default to administrator privileges.

Error responses

When the IPI receives a valid SIS command, it executes the command and sends a

response to the host device. If the IPI is unable to execute the command because

the command is invalid or it contains invalid parameters, it returns an error

response to the host.
The error response codes and their descriptions are as follows:
E12 – Invalid port number

E13 – Invalid value (the number is out of range/too large)

E14 – Not valid for this configuration

E17 – System timed out

E22 – Busy

E24 – Privilege violation

E26 – Maximum number of connections has been exceeded

E27 – Invalid event number

E28 – Bad filename or file not found

E30 – Hardware failure (followed by colon and descriptor number) (This is an

unsolicited response.)

E31 – Attempt to break port pass‑through when not set

Error response references

The following superscripted numbers are used within the command descriptions

on the following pages to identify commands that may respond as shown:

14

= Commands that give an E14 (not valid for this configuration) response if the

unit’s current configuration doesn’t support that command.

22

= Commands that yield an E22 (busy) response.

24

= Commands that give an E24 (privilege violation) response if you are not logged

in at the administrator level.

27

= Commands that may yield an E27 (invalid event number) response.

28

= Commands that may give an E28 (file not found) response.