SIS Programming and Control, cont’d

IPI 100 and IPI 200 Series • SIS Programming and Control

B-6

X1#

= Local date and time format

Set

format (MM/DD/YY‑HH:MM:SS).

Example: 01/18/05-10:54:00.

Read

format (day of week, date month year HH:MM:SS).

Example: Tue, 18 Jan 2005 18:19:33.

X1$

= IP address or subnet mask (xxx.xxx.xxx.xxx). Leading zeros in each of four

fields are optional in setting values, and they are suppressed in returned

values.

IPI’s default address: 192.168.254.254

Default broadcast address: 255.255.255.255.

X1*

= Hardware (MAC) address (xx‑xx‑xx‑xx‑xx‑xx) (00‑05‑A6‑xx‑xx‑xx)

X2@

= Verbose/response mode status:

0

= clear/none, default for Telnet connections; responses are not echoed to

the host

1

= verbose mode is on, default for RS‑232 host control; responses are echoed

to the host and displayed to the user

2

= send tagged responses for queries

3

= verbose mode is on and tagged responses are sent for queries

N

If tagged responses are enabled, all read commands return the constant string +

data, the same as for setting a value. For example, for

E

CN

}

, the response

is Ipn•

X1@ ]

rather than just the data.

X3#

= Password (minimum length = 4 characters, maximum length = 12 characters,

no special characters are allowed)

N

A user password cannot be assigned if no administrator password exists; the E14

error code will be returned. If the administrator password is cleared, then the
user password is also removed.

X3$

= Daylight saving time

0

= Daylight Saving Time off/ignore

1

= Daylight Saving Time on (USA/Canada)

2

= Daylight Saving Time on (Europe)

3

= Daylight Saving Time on (Brazil)

X4!

= Password to display on screen (response to password query or set). When

the MLC connects to a host device via RS‑232, the password (

X3#

), itself, is the

response. When the connection is via IP,

X4!

is 4 asterisks (****) if a password

has been assigned, or it is an empty field ( ) if a password hasn’t been

assigned.

X4(

= Default name: a combination of the model name and the last 3 pairs of the

IPI 200 series’ MAC address

X5@

= Connection’s security level

11 = user

12 = administrator

X6#

= Pulse time in 20 ms per count. If this parameter is missing or = 0, then pulse

length = default = 25 = 500 ms. 1 = 20 ms (minimum pulse time) to 65535 =

1310700 ms (maximum pulse time).