Extron Electronics IPI 200 Series User Guide User Manual
Page 17
2-3
IPI 100 and IPI 200 Series • Installation
Å
LAN port (IPI 201 AAP and 204 AAP only) — Plug an RJ‑45 jack into the LAN
connector to connect to a network. The blinking yellow LED indicates LAN
activity. The green LED lights to indicate a good LAN connection.
Patch (straight-through) cable
Side 1
Side 2
Pin Wire color Pin Wire color
1 White-orange
1 White-orange
2 Orange
2 Orange
3 White-green
3 White-green
4 Blue
4 Blue
5 White-blue
5 White-blue
6 Green
6 Green
7 White-brown
7 White-brown
8 Brown
8 Brown
Crossover cable
Side 1
Side 2
Pin Wire color Pin Wire color
1 White-orange
1 White-green
2 Orange
2 Green
3 White-green
3 White-orange
4 Blue
4 Blue
5 White-blue
5 White-blue
6 Green
6 Orange
7 White-brown
7 White-brown
8 Brown
8 Brown
Clip Down
Side
1
1&2
3&6 4&5
7&8
234567 8
Pins
12345678
RJ-45
connector
Twisted
Pairs
b
AAP mounting screws — These four screws are permanently attached to the IPI’s
faceplate. They are used for mounting the faceplate into another device (such as an
MLC 226 IP AAP) or a mounting frame.
N
Items
c
to
e
apply only to the IPI 201 and IPI 204 models.
c
Power —
Connect a cable between the 2‑pole, 3.5,mm captive screw connector and
a 12 VDC, 1 A power supply (included).
C
The power supply shall not be permanently fixed to the building structure
or similar structures.
The power supply shall not be located within environmental air handling
spaces or within the wall cavity.
The installation shall be in accordance with the applicable provisions of
the
National Electrical Code ANSI/NFPA 70, Article 725 and the
Canadian Electrical Code, Part 1, Section 16.
The power supply is to be located within the same vicinity as the Extron
equipment in an ordinary location, Pollution Degree 2, secured to the
equipment rack within the dedicated closet, podium or desk.
d
Contact Relay —
The 2‑pole, 3.5,mm captive screw contact relay connector is used
to control items such as room lighting, window coverings, and door locks. The
contact may be used to control any equipment as long as the contact specifications
of 24 VDC at 1 A are not exceeded.
e
Audio Out —
A 3‑pole, 3.5 mm captive screw connector is used for audio output
connection. It provides a ‑10 dBV balanced or unbalanced signal that can be
connected to local, powered speakers or to any audio or paging system.