Å

LAN port (IPI 201 AAP and 204 AAP only) — Plug an RJ‑45 jack into the LAN

connector to connect to a network. The blinking yellow LED indicates LAN

activity. The green LED lights to indicate a good LAN connection.

Patch (straight-through) cable

Side 1

Side 2

Pin Wire color Pin Wire color

1 White-orange

1 White-orange

2 Orange

2 Orange

3 White-green

3 White-green

4 Blue

4 Blue

5 White-blue

5 White-blue

6 Green

6 Green

7 White-brown

7 White-brown

8 Brown

8 Brown

Crossover cable

Side 1

Side 2

Pin Wire color Pin Wire color

1 White-orange

1 White-green

2 Orange

2 Green

3 White-green

3 White-orange

4 Blue

4 Blue

5 White-blue

5 White-blue

6 Green

6 Orange

7 White-brown

7 White-brown

8 Brown

8 Brown

Clip Down

Side

1

1&2

3&6 4&5

7&8

234567 8

Pins

12345678

RJ-45

connector

Twisted

Pairs

b

AAP mounting screws — These four screws are permanently attached to the IPI’s

faceplate. They are used for mounting the faceplate into another device (such as an

MLC 226 IP AAP) or a mounting frame.

N

Items

c

to

e

apply only to the IPI 201 and IPI 204 models.

c

Power —

Connect a cable between the 2‑pole, 3.5,mm captive screw connector and

a 12 VDC, 1 A power supply (included).
C

The power supply shall not be permanently fixed to the building structure
or similar structures.

The power supply shall not be located within environmental air handling
spaces or within the wall cavity.

The installation shall be in accordance with the applicable provisions of
the

National Electrical Code ANSI/NFPA 70, Article 725 and the

Canadian Electrical Code, Part 1, Section 16.

The power supply is to be located within the same vicinity as the Extron
equipment in an ordinary location, Pollution Degree 2, secured to the
equipment rack within the dedicated closet, podium or desk.

d

Contact Relay —

The 2‑pole, 3.5,mm captive screw contact relay connector is used

to control items such as room lighting, window coverings, and door locks. The

contact may be used to control any equipment as long as the contact specifications

of 24 VDC at 1 A are not exceeded.

e

Audio Out —

A 3‑pole, 3.5 mm captive screw connector is used for audio output

connection. It provides a ‑10 dBV balanced or unbalanced signal that can be

connected to local, powered speakers or to any audio or paging system.

This manual is related to the following products: