IPI 100 and IPI 200 Series • Specifications, Part Numbers, Accessories

A-4

Specifications — IPI 200 Series

Audio

Speaker ........................................... 1.4" (35.6 mm), 1‑way, indoor
Frequency response

Line level output ............... 20 Hz to 3.3 kHz, ±1 dB
Speaker output .................. 300 Hz to 3.3 kHz, ‑10 dB

Nominal sensitivity/IPI speaker output level

80 dB SPL, 300 mW, 3' (1 m)

Processing

Audio format ..................... PCM, µ‑law companded
Sampling rate ..................... 8 kHz
Sample size ......................... 16 bit, µ‑law companded to 8 bit
Audio latency..................... <100 ms

Audio input

Number/signal type ..................... 1 mono, via integrated electret microphone
Microphone gain ........................... ‑30 dB to 0 dB, adjustable in 2 dB steps

N

0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu

Audio output

Number/signal type ..................... 2 mono: 1 via audio output port, 1 via IPI speaker
Line level output ........................... ‑10 dBV (316 mVrms), balanced/unbalanced (via 3.5 mm captive screw

connector, 3 pole)

Amplified speaker output ............ 300 mW, continuous, 1% THD

Ethernet control interface

Ethernet control/communications port

1 female RJ‑45 connector

Ethernet data rate/transport bandwidth

80 kbps

Communications type .................. Half duplex
Ethernet protocol ........................... IP (control), TCP (control), UDP (port 3121, audio), Telnet
Default settings .............................. Link speed and duplex level: autodetected

IP address = 192.168.254.254

Subnet mask = 255.255.0.0

Default gateway = 0.0.0.0

DHCP = off

Program control ............................. Extron control/configuration program for Windows

®

Extron Simple Instruction Set (SIS

)

Microsoft

®

Internet Explorer ver. 6 or higher, Telnet

Control — relay

Number/type ................................ 1 momentary or latching (configurable)
Connector ....................................... (1) 3.5 mm captive screw connector, 2 pole, C (common) and NO (normally

open) for configurable relay output

Contact rating ................................ 24 V, 1 A