Dh-21 – Xylem DH-21 User Manual
Page 65

DH-21
Using the Graphical “W
ATER
LOG” Software 4-19
Hyper Limit:
The Hyper Limit will be expressed in the unit of measure specified under the conversion
options with inches, feet, meters, PSI, etc., being common units for this field. As long as
the difference between the current scanned level and the last logged level is less than this
set hyper limit, the scan rate will stay at the regular rate. If the difference is greater than
the set hyper limit, the scan rate will jump to a faster preset scan rate.
Hyper Divisor:
The Hyper Divisor is used to determine the faster scan rate. The faster scan rate is
calculated by taking the regular scan rate and dividing it by the hyper divisor. The hyper
divisor must be able to be divided into the regular scan rate without a remainder or it will
default to 1. For example, if the regular scan rate is 1 minute, the following hyper divisors
are valid:
SCAN RATE
HYPER DIVISOR
FAST SCAN RATE
1 minute
60
1 seconds
1 minute
30
2 seconds
1 minute
20
3 seconds
1 minute
15
4 seconds
1 minute
12
5 seconds
1 minute
10
6 seconds
1 minute
6
10 seconds
1 minute
5
12 seconds
1 minute
4
15 seconds
1 minute
3
20 seconds
1 minute
2
30 seconds
1 minute
1
60 seconds