beautypg.com

Dh-21 – Xylem DH-21 User Manual

Page 48

background image

4-2 Using the Graphical “W

ATER

LOG” Software

DH-21

The following will be displayed on the screen.

Wrong number of parameters have been specified.

WATERLOG ; < > = Optional

DEFAULT : (STAND = 1, COM = 2)

STAND:

1 = CONNECT
2 = STAND-ALONE
3 = STAND-ALONE ONLY

COM :

1 = COM1
2 = COM2

Example 1:

WATERLOG
Uses defaults (CONNECT) (COM2)

Example 2:

WATERLOG 2 1
Uses user defined (STAND-ALONE) (COM1)

Note: WATERLOG.EXE uses the standard IBM PC serial port interrupt configuration;
IRQ4 for COM1 and IRQ3 for COM2.

The master disk contains several files. The list below shows all the files that are required to run
the program except for the *.HLP files. The *.HLP files are the help files and if not present, will
prevent any on line help.

WATERLOG.EXE

; main program

DOS4GW.EXE

; program to use upper memory

PMINFO.EXE

; diagnostic program to see memory usage

WATERLOG.WSF

; sample “

W

ATER

LOG” setup file

TEST.DAT

; sample data file

FNT8X8.BIN

; font file

*.HLP

; help files (27)

4.3 Overview of Options

The screen of the computer is updated every 5 seconds with the logger time, date and sensor data.
When the

W

ATER

WARE

TM

program is running, it issues a command to the “

W

ATER

LOG

telling it to provide the information displayed on the next screen update. When connected to the

W

ATER

LOG” and running the

W

ATER

WARE

TM

program, the “

W

ATER

LOG” will change to a

continuous operating-power mode from the low-power mode to be able to respond to commands
from the computer. This continuous operation shortens battery life and should not be used for
long periods in the field unless you are willing to replace the battery more frequently. However,
an external 12 volt power source can be connected via the RS-232 communications connector to
elevate power drain on internal lithium battery pack.