3-18 Using the “W

ATER

LOG” Software

DH-21

The WaterLOG Serial # T2000 Version 1.1

Status = RESET (VARIABLE) Last Measurement Units
Date/Time = 02/28/95 03:57:35
Date Started = 01/01/95 14:39:00 PRESSURE = 0.0000 PSI
Logging Rate = 00:00:05 TEMPERATURE = 0.00 Deg F
Next Log Time = 00:00:00
Memory Used = 0.0 %
Logging Count = 0 Scans
Battery = 6.8 Volts


1) Run 4) Time/Date 7) User Notes 10) Measure Data
2) Off 5) Logging Mode 8) Extract Data 11) Zero Sensor
3) Reset 6) Coefficients 9) View Data 12) Sensor Info
13) Diagnostics
Enter Option: 1 Esc-Exit

Run

This will start the sensor logging.
Enter Start Time: 04:00:00 (00:00:00 to 23:59:59)
Esc-Exit

Figure 3-13. Run Option/ Start Time

There are several options which will not execute in the RUN mode of operation because they
disrupt the logging process. These options are 4, 5, 10, and 13.

3.2.7 Off or Stop Logging Option

The sensor can be paused and the logging operation halted by entering the OFF mode. The OFF
mode allows the execution of the options not allowed in the RUN mode except for option 13,
which can only be executed in the RESET mode of operation. Figure 3-14 shows how the OFF
mode is invoked. You must confirm this option by typing to prevent inadvertent operation.