DH-21

Using the “W

ATER

LOG” Software 3-19

The WaterLOG Serial # T2000 Version 1.1

Status = RUN (VARIABLE) Last Measurement Units
Date/Time = 02/28/95 04:07:17
Date Started = 02/28/95 04:00:00 PRESSURE = -0.0052 PSI
Logging Rate = 00:01:00 TEMPERATURE = 78.07 Deg F
Next Log Time = 04:07:55
Memory Used = 0.1 %
Logging Count = 15 Scans
Battery = 6.8 Volts


1) Run 4) Time/Date 7) User Notes 10) Measure Data
2) Off 5) Logging Mode 8) Extract Data 11) Zero Sensor
3) Reset 6) Coefficients 9) View Data 12) Sensor Info
13) Diagnostics
Enter Option: 2 Esc-Exit

Off

This will stop the sensor logging.
Continue? y (y/n)
Esc-Exit

Figure 3-14. Stop Logging Option

3.2.8 Extract Data Option

You will use the Extract Data option to retrieve the data stored in the FLASH EEPROM of the

W

ATER

LOG” using option number 8 as shown in Figure 3-15. You can choose to transfer all

the data stored in the “

W

ATER

LOG” or transfer only the new data stored since the previous

download.

The WaterLOG Serial # T2000 Version 1.1

Status = OFF (VARIABLE) Last Measurement Units
Date/Time = 02/28/95 04:07:59
Date Started = 02/28/95 04:00:00 PRESSURE = -0.0052 PSI
Logging Rate = 00:01:00 TEMPERATURE = 78.07 Deg F
Next Log Time = 04:07:55
Memory Used = 0.1 %
Logging Count = 15 Scans
Battery = 6.8 Volts


1) Run 4) Time/Date 7) User Notes 10) Measure Data
2) Off 5) Logging Mode 8) Extract Data 11) Zero Sensor
3) Reset 6) Coefficients 9) View Data 12) Sensor Info
13) Diagnostics
Enter Option: 8 Esc-Exit

Extract Data

1) Extract ALL Data 2) Extract NEW Data

Enter Option: 1 Esc-Exit

Figure 3-15. Extract Data Option