Logging out of the galaxy gateway, A - 12 – GE Industrial Solutions Galaxy Vector Controller GCM3 User Manual
Page 90

Galaxy Vector Controller GCM2, GCM3
Appendix A - 12 Communications
Issue 4 January 2008
*note: 1) commands are not case sensitive
2) for the commands that follow, ddd is a number from 0
- 255
• To set the IP Address, type:
CHA NET1,IP=ddd.ddd.ddd.ddd
Verify by typing:
STA NET1,IP
• To set the Subnet mask, type:
CHA NET1,SUB=ddd.ddd.ddd.ddd
Verify by typing:
STA NET1,SUB
• Optional:
To set the Default Gateway Address, type:
CHA NET1,GTWY=ddd.ddd.ddd.ddd
Verify by typing:
STA NET1,GTWY
• Optional:
To set the Host Name, type:
CHA NET1,HOST=host name
Verify by typing:
STA NET1,HOST
Logging Out of
the Galaxy
Gateway
To terminate the configuration session, enter the “bye”
command. The Galaxy Gateway will notify the user if
configuration is not complete. This message will have the
following format:
NOTICE:
Default gateway may be required for network
access.
Host Name may be required for network access.
Logging off...
Messages referencing the Gateway and Host Name are
acceptable, since these parameters are optional.
Note: If the IP address or Subnet mask messages appear, for
example:
IP Address is required for network access.
Subnet mask is required for network access.