8. Optional BFT Ladder Assembly

30

PNEG-1460 6', 7' and 9' Bulk Feed Tank BFT Series and GHT Series

Starter Bracket Installation

The starter brackets must be centered in the roof sheet to ensure proper installation of the roof ladder
support brackets. Before the starter brackets can be installed, two (2) 3/8" holes must be drilled. The
holes must be 2.66" below and directly in line with the top row of pre-punched horizontal holes 18-3/4"
apart. Refer to

Figure 8B

for additional clarification of hole locations. Use 5/16" and 1" bin bolts

for connections.

Figure 8B

Ref #

Description

A

Two (2) 3/8" Field Drilled Holes

B

Roof Panel

C

Top Horizontal Seam

D

3/8" Field Drilled Holes

E

Sidewall Sheet

F

L.H. 30° Roof (LDR-5405) and R.H. 30° Roof (LDR-5406)

L.H. 40° Roof (LDR-5407) and R.H. 40° Roof (LDR-5408)