beautypg.com

Recorder, Remote mode, Port – EVS XT2 Version 11.02 - July 2013 Configuration Manual User Manual

Page 212: Protocol

background image

Recorder

Description

Selects the record channel to which the A/V material from the
hypermotion camera will be sent.

Values

CAM A to CAM D

Default Values

The default value is the last CAM defined in the channel
configuration (for ex. CAM C in a 3 IN 3 OUT configuration).

Remote mode

Description

Specifies the camera elements controlled by the server.

Values

Hypermotion only:
The server controls only the hypermotion camera. An
additional remote is made available in the main menu of the
remote panel, since the hypermotion camera is considered
as an additional external camera.

Hypermotion + LSM:
The server controls the hypermotion camera and one PGM
in exclusive mode.

Default value

Hypermotion only

Port

Description

Specifies on which port (RS422 or Lan PC) the commands
must be sent to the hypermotion camera, and possibly to the
PGM if you have selected ‘Hypermotion + LSM” in the Remote
Mode
parameter.

Values

The following values are possible:

RS422 #2 to RS422 #6

Lan PC

Default value

RS422 #6

Protocol

Description

Specifies the protocol type used for data transfer on the
selected port.

Values

The following values are possible:

TCP / UDP (when Port is set to Lan PC).

ASCII / Sony 9-pin (when Port is set to one of the RS422).

Default values

TCP (when Port is set to Lan PC).

Sony 9-pin (when Port is set to one of the RS422).

204

3. Multicam Configuration

EVS Broadcast Equipment S.A.

Issue 11.02.A July 2013