User accounts – AASTRA BluStar 8000i BAS-Mode Administrator Guides EN User Manual
Page 56
User Accounts
5-7
41-001391-00 Rev 03 – 04.2012
Minimum Number of Digits in Password
Sets the minimum number of digits that must be in a password. Setting this to “0” (zero) disables checking.
Minimum Number of Special Characters in Password
Sets the minimum number of special characters that must be in a password. Setting this to “0” (zero) disables
checking.
Special Characters Allowed in Password
Lists of special characters that are allowed to be entered in a password. Setting this to “All” enables any special
character to be used.
Password Expiry
Max Password Age
Sets the maximum number of days that the current password remains valid. Setting this to 0 (zero) disables check-
ing.
Password History
Sets the number of previous passwords that are “remembered” by the system. New passwords cannot match any of
the passwords in the history.
Account Lock
Number of Invalid Login Attempts before User Account Lock
Sets the number of invalid login attempts that the system permits before locking the account. Setting this to 0
(zero) disables checking.
Account Lock Time
Sets the time (in minutes) that the account remains locked if the number of invalid login attempts is exceeded. This
setting is disabled if the Number of Invalid Login Attempts before User Account Lock field is set to 0 (zero).