beautypg.com

Internal sptgen ftp download example – ZyXEL Communications ADSL VoIP IAD with 802.11g Wireless 2602HW Series User Manual

Page 464

background image

Prestige 2602HW Series User’s Guide

464

Some parameters are dependent on others. For example, if you disable the Configured field in
menu 1 (see

Figure 288 on page 463

), then you disable every field in this menu.

If you enter a parameter that is invalid in the Input column, the Prestige will not save the
configuration and the command line will display the Field Identification Number.

Figure

289 on page 464

, shown next, is an example of what the Prestige displays if you enter a value

other than “0” or “1” in the Input column of Field Identification Number 1000000 (refer to

Figure 288 on page 463

).

Figure 289 Invalid Parameter Entered: Command Line Example

The Prestige will display the following if you enter parameter(s) that are valid.

Figure 290 Valid Parameter Entered: Command Line Example

Internal SPTGEN FTP Download Example

1 Launch your FTP application.

2 Enter "

bin

". The command “

bin

” sets the transfer mode to binary.

3 Get "

rom-t

" file. The command “

get

” transfers files from the Prestige to your computer.

The name “

rom-t

” is the configuration filename on the Prestige.

4 Edit the "

rom-t

" file using a text editor (do not use a word processor). You must leave

this FTP screen to edit.

field value is not legal error:-1
ROM-t is not saved, error Line ID:10000000
reboot to get the original configuration
Bootbase Version: V2.02 | 2/22/2001 13:33:11
RAM: Size = 8192 Kbytes
FLASH: Intel 8M *2

Please wait for the system to write SPT text file(ROM-t)...
Bootbase Version: V2.02 | 2/22/2001 13:33:11
RAM: Size = 8192 Kbytes
FLASH: Intel 8M *2