Zebra Technologies XiII-Series User Manual
Page 76
Symptom
Diagnosis
Action
A label format was sent to the
printer but not recognized.
Communications
parameters are incorrect.
Print a Communications
Diagnostic label. Check for
Format or Overrun Errors. See
"Setting Communication
Parameters" on page 38.
Prefix and delimiter
characters set in printer do
not match the ones used in
the label format.
Set the characters in the
printer to match the label
format. See Selecting Prefix
and Delimiter Characters on
page 40.
If the problem continues,
check the ZPL II format for
changed ^CC, ^CT, and
^CD commands.
A label format was sent to the
printer but not recognized.
Data light flashes but no
printing occurs.
Communications
parameters are incorrect.
Print a Communications
Diagnostic label. Check for
Format or Overrun Errors. See
"Setting Communication
Parameters" on page 38.
Prefix and delimiter
characters set in printer do
not match the ones used in
the label format.
Set the characters in the
printer to match the label
format. See Selecting Prefix
and Delimiter Characters on
page 40.
If the problem continues,
check the ZPL II format for
changed ^CC, ^CT, and
^CD commands.
A batch of labels was sent.
Several labels print then
printer skips, misplaces,
misses, or distorts the
printing on the labels.
Buffer is overfilling.
Check for proper flow control
setting. Refer to Configuration
and Calibration.
64
Zebra
XiII-Series User’s Guide
76
H:...Xi2UsersGuideR2.vp
Fri Aug 07 10:36:38 1998
Color profile: Disabled