Press

Display Shows

Action/Explanation

APPLICATOR

PORT

Setting the Applicator Port

Press the right or left oval key

to display other choices.
Default: Off Selections: Off, Mode 1, Mode 2, Mode 3, Mode 4
Determines the action of the verifier port.
• Off—The applicator port is off.
• Mode 1—Asserts the ~END_PRINT signal low while the

printer is moving the label forward.
• Mode 2—Asserts the ~END_PRINT signal high while the

printer is moving the label forward.
• Mode 3—Asserts the ~END_PRINT signal low for 20

milliseconds when a label has been completed and

positioned. Not asserted during continuous printing modes.
• Mode 4—Asserts the ~END_PRINT signal high for 20

milliseconds when a label has been completed and

positioned. Not asserted during continuous printing modes.

WEB S.

These parameters are automatically set during the calibration

procedure. They should only be changed by a qualified

service technician. Refer to the maintenance manual for more

information on these parameters.
Press the Next/Save key repeatedly to skip these parameters.

MEDIA S.

RIBBON S.

MARK S.

MARK MED S.

MEDIA LED

RIBBON LED

MARK LED

44

Zebra XiII-Series User’s Guide

56

H:...Xi2UsersGuideR2.vp

Fri Aug 07 10:35:51 1998

Color profile: Disabled