Press
Display Shows
Action/Explanation
APPLICATOR
PORT
Setting the Applicator Port
Press the right or left oval key
to display other choices.
Default: Off Selections: Off, Mode 1, Mode 2, Mode 3, Mode 4
Determines the action of the verifier port.
OffThe applicator port is off.
Mode 1Asserts the ~END_PRINT signal low while the
printer is moving the label forward.
Mode 2Asserts the ~END_PRINT signal high while the
printer is moving the label forward.
Mode 3Asserts the ~END_PRINT signal low for 20
milliseconds when a label has been completed and
positioned. Not asserted during continuous printing modes.
Mode 4Asserts the ~END_PRINT signal high for 20
milliseconds when a label has been completed and
positioned. Not asserted during continuous printing modes.
WEB S.
These parameters are automatically set during the calibration
procedure. They should only be changed by a qualified
service technician. Refer to the maintenance manual for more
information on these parameters.
Press the Next/Save key repeatedly to skip these parameters.
MEDIA S.
RIBBON S.
MARK S.
MARK MED S.
MEDIA LED
RIBBON LED