36-pin

Connector

Description

14

nAutoFd (not connected)

15

Not defined

16

Logic Gnd

17

FRAME GROUND is at the same potential as Logic Gnd (pin 16).

18

FUSED 5 V - 1 A maximum.

19-30

SIGNAL GROUNDS are the Logic Grounds and Returns for all input and output

signals.

31-35

NOT USED - These leads should be left unconnected.

36

NSelectIn (not connected)

Cabling Requirements

Data cables must be fully shielded and fitted with metal or metalized con-
nector shells. Shielded cables and connectors are required to prevent radia-
tion and reception of electrical noise.

To minimize electrical noise pickup in the cable:

n

Keep data cables as short as possible.

n

Do not bundle the data cables tightly with the power cords.

n

Do not tie the data cables to power wire conduits.

NOTES: Zebra printers comply with FCC “Rules and Regulations”,

Part 15, Subpart J, for Class A Equipment, using fully shielded
6-foot data cables. Use of longer cables or unshielded cables
may increase radiated emissions above the Class A limits.

RS-422 and RS-485 applications should use twisted shielded

pairs as recommended in the Appendix of the TIA/EIA-485

Specification.