Telenetics 56 User Manual
Page 89
AT Commands
Page 81
5 LAPM error control required; disconnect if error
control is not established.
6 MNP error control required; disconnect if error
control is not established.
8 Initiate V.80 Synchronous Access Mode when
connection is completed, and Data State is
entered (see +ESA and +ITF commands).
9 9Initiate Frame Tunneling Mode when
connection is complete, and Data Mode is
entered
Examples
+ES=6 Enable V.80 Synchronous Access Mode
originator.
+ES=6 Enable V.80 Synchronous Access Mode
originator.
Enable V.80 Synchronous Access Mode
answerer.
+ES=6,,8 Enable V.80 Synchronous Access Mode
originator and answerer.
+ES=3 Enable V.42 with Detection Phase originator.
Disable V.80 Synchronous Access Mode
originator.
+ES=,, 2 Allow LAPM, MNP, or Normal Mode
connection answerer. Disable V.80
Synchronous Access Mode answerer.
+ES=3,,2 Enable V.42 with Detection Phase originator,
allow LAPM, MNP, or Normal Mode connection
answer. Disable Synchronous Access Mode
originator and answerer.
Reporting Current or Selected Values
Command: +ES?
Response: +ES:
Example:
+ES: 3,0,2 For the default setting.
+ES: 6,0,8 For V.80 Synchronous Access Mode originator and
answerer.
Reporting Supported Range of Parameter Values
Command: +ES=?
Response:
+ES: (
range)
Example: +ES:
(0-4,6,7),(0-4),(0-6,8,9)
+EB - Break Handling in Error Control Operation
This extended-format compound parameter controls the break handling in V.42
operation. It accepts three numeric subparameters:
Syntax
+EB=[
]
Defined Value
> Decimal number 0 specifying that break is to be ignored, i.e., SIGNAL will not indicate break signal length DTE. Reporting Current or Selected Values
not signaled to remote DCE.