AT Commands
Page 150
Example: (0,1,2,4,8,10,18)
+FMI? - Request Manufacturer Identification
This command causes the modem to report the modem product manufacturer.
Syntax
+FMI?
Typical Response
CONEXANT
OK
+FMM? - Request Model Identification
This command causes the modem to report the modem product model.
Syntax
+FMM?
Typical Response
V90
OK
+FMR? - Request Revision Identification
This command causes the modem to transmit one or more lines of information text
identifying the modem version, revision level or date.
Syntax
+FMR?
Typical Response
V3.001-V90_2M_DLS
OK
+FLO - Flow Control
This parameter allows the DTE to identify and select the type of flow control used.
Syntax
+FLO=
Defined Values
0 XON/XOFF and RTS/CTS flow control turned off.
1 Use XON/XOFF flow control in either direction.
2 Use RTS for flow control of the modem by the DTE;
use CTS for flow control of the DTE by the modem.
Reporting Current or Selected Values
Command: +FLO?
Response: +FLO
Example
+FLO: 0
For the default setting.
Reporting Supported Range of Parameter Values
Command: +FLO=?
Response: +FLO:
(
Example: +FLO:
(0-2)
Result Codes
OK
ERROR Otherwise.