Telenetics 56 User Manual
Page 172
AT Commands
Page 164
1*
2-D modified Read
2*
2-D
uncompressed
mode
3*
2-D modified
modified Read
EC
Error Correction
0
Disable ECM
(Annex A/T.30)
1*
Enable ECM, 64
bytes/frame
2*
Enable ECM, 256
bytes/frame
BF
Binary File Transfer 0
Disable BFT
1*
Enable BFT
ST
Scan Time/Line
VR = normal
VR = fine
0
0 ms
0 ms
1
5 ms
5 ms
2
10 ms
5 ms
3
10 ms
10 ms
4
20 ms
10 ms
5
20 ms
20 ms
6
40 ms
20 ms
7
40 ms
40 ms
Notes
:
1. CCITT T.30 does not provide for the answering station to specify all
speeds exactly using the DIS frame.
Implementation of some BR codes (e.g., code 2) by an answering DCE
is manufacturer specific. .
* Not supported
+FET - Transmit Page Punctuation
Syntax
+FET=
DCE response:
+FPTS: > - when receive from remote OK This command is used to punctuate page and document transmission after one or more The +FET= The DTE can command the DCE to generate PRI-Q messages with the +FET=<ppm> This command must be sent within the time out specified by +FPHCTO after sending session.
+FDT commands. This command generates T.30 Post Page Messages selected by the
will be appended to it. The value indicates whether there are any additional pages are to
be sent and, if so, whether there is a change in any of the document parameters.
command using ppm codes 4-6 (Table A-24).
Phase C data, or else the DCE will end the page and document transmission. If the Phase
C timeout is reached, the DCE sends an EOP post page message and terminates the