Telenetics 56 User Manual
Page 128
AT Commands
Page 120
S29 - Flash Dial Modifier Time
S29 sets the length of time, in units of 10 ms, that the modem will go on-hook when it
encounters the flash (!) dial modifier in the dial string. S29 is a country dependent
parameter. The S29 value cannot be changed using S29=XX.
Range:
0-255 10 ms intervals
Default:
70 (700 ms) for U.S.
S30 - Disconnect Inactivity Timer
S30 sets the length of time, in tens of seconds, that the modem will stay online before
disconnecting when no data is sent or received. In error-correction mode, any data
transmitted or received will reset the timer. In other modes, any data transmitted will
reset the timer. The timer is inoperative in synchronous mode.
Range:
0-255 tens of seconds (0-2550 seconds)
Default:
0 (disabled)
S31 - Bit Mapped Options Status
S31 indicates bit mapped options status.
Default: 192 (C0h) (11000000b)
Bit 0
Single line connect message enable/disable (\Vn)
0 =
Messages controlled by S95, Wn and Vn (\V0) (Default.)
1 =
Single line connect message (\V1)
Bit 1 Reserved (0)
Bits 2-3
Error correction progress messages (Wn)
0 =
DTE speed only (W0) (Default.)
1 =
Full reporting (W1)
2 =
DCE (line) speed only (W2)
Bits 4-5
Caller ID (+VCID)
0 =
Caller ID disabled (+VCID=0) (Default.)
1 =
Short (formatted) Caller ID enabled (+VCID=1)
2 =
Long (unformatted) Caller ID enabled (+VCID=2)
Bits 6-7
Reserved (Default = 11b)