A.4 station clk connector – lrsi-f-cm2 modules – RAD Data comm LRS-24 User Manual
Page 87
LRS-24 Installation and Operation Manual
Appendix A Connector Wiring
Station CLK Connector – LRSI-F-CM2 Modules
A-3
Table A-3. Pin Allocation for Management RS-232 Connector on
CM-1/CM-2 Modules (Cont.)
Pin
Function
Direction
7
Request to Send (RTS)
Connected to pins 1, 8
8
Clear to Send (CTS)
Connected to pins 1, 7
9
Ring Indicator (RI)
N/A
A.4 Station CLK Connector – LRSI-F-CM2 Modules
The station clock interface located on the LRSI-F-CM2 modules are terminated in
a 15-pin D-type female connector, designated STATION CLK, and wired in
accordance with Table A-4.
The connector also includes the contacts of the major and minor alarm relays.
Table A-4. Pin Allocation for LRSI-F-CM2 Modules, Station Clk Connector
Pin
Function
1
Station Clock Transmit Output (tip)
2
Not Connected
3
Station Clock Receive Input (tip)
4, 5
Not Connected
6
Minor Alarm Relay – Normally Closed (NC) to pin 14
7
Major Alarm Relay – Normally Open (NO) relative to pin 8
8
Major Alarm Relay – Common Contact
9
Station Clock Transmit Output (ring)
10
Not Connected
11
Station Clock Receive Input (ring)
12
Not Connected
13
Minor Alarm Relay – Normally Open (NO) relative to pin 14
14
Minor Alarm Relay – Common Contact
15
Major Alarm Relay – Normally Closed (NC) to pin 8