D.9 defining i/o module operational parameters, Purpose, Format – RAD Data comm LRS-24 User Manual
Page 122: Procedure
Appendix D CM-2 Management Commands
LRS-24 Installation and Operation Manual
D-20
Defining I/O Module Operational Parameters
A card containing four modems, such as ASMI-31CQ, is defined for four remote
modems.
When you select UNLINKED for Remote1, Remote2, Remote3, or Remote4, then
traps from the remote modem are masked.
D.9 Defining I/O Module Operational Parameters
Purpose
Defines the operational parameters for an I/O module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal, for example ASMi-24,
ASMi-30, ASMi-31, ASMi-32, etc. For such modules, the CM-2 module provides
the terminal interface.
Format
NODE nn DEF PRM
Procedure
➤
To define I/O Module Operational Parameters:
• Type: NODE nn DEF PRM
nn stands for the node number of the desired module, in the range of
1 through 12.
The first line of the module data entry form appears (see Figure D-19).
Note
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com