beautypg.com

Performing preliminary configuration, Configuring individual modules – RAD Data comm LRS-24 User Manual

Page 63

background image

LRS-24 Installation and Operation Manual

Chapter 3 Management via the CM-1 Module

Operating the CM-1 Supervision Terminal

3-5

4. Connect the communication cable of the supervision terminal to either the

management RS-232 connector on the LRSI-F-CM1 module (serving the CM-1
module), or to the connector with the same name located on the CM-1
module (refer to Section 3-2 for details).

5. Make sure LRS-24 is powered. Turn on the supervision terminal. When

applicable, also turn on the modems and any other communication
equipment used to connect the terminal to LRS-24.

You are now ready to start the configuration session.

For instructions on how to select default communication parameters, default

terminal type and default password, refer to the Installation and Operation Manuals
for the various modules.

Performing Preliminary Configuration

Perform the following activities on each module that is to be managed by means of
the supervision terminal:

To configure each module:
1. Define the terminal type you are using by entering the command

NODE nn

, followed by the command used to define the terminal type for the

desired module, i.e.,

DEF TERM

.

2. To change the communication parameters after establishing communication:

Use the command

NODE nn DEF SP

.

3. To change the current password: Use the command

NODE nn DEF PWD

.

In the following sections, nn represents the number of the slot in which the desired
module is installed.

Configuring Individual Modules

After completing the preliminary configuration, start the configuration of the
individual I/O modules. Before each command, add the prefix

NODE nn

.

Note

Note

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com