LRS-24 Installation and Operation Manual
Chapter 1 Introduction
Technical Specifications
1-15
External Clock Interface
T1 Mode
Type
T1
Clock Rate
1.544 MHz
Line Interface
100Ω
Ω
Ω
Ω, balanced
Line Code
Bipolar AMI
Receive Level
0 through -10 dB
Transmit Level
±3V ±10%, balanced
E1 Mode
Type
E1
Bit Rate
2.048 MHz
Line Interface
120Ω, balanced
75Ω, unbalanced
Line Code
AMI
Receive Level
0 through -10 dB
Transmit Level
±3V ±10%, balanced
±2.73V ±10%, unbalanced
Square
Minimum 2.2V peak-to-peak amplitude
CM-1 Management Interface
Functionality
Transparent interfacing to internal management ports of
I/O modules
Hardware
RS-232 asynchronous port, compatible with
VT-52, VT-100, FREEDOM-100, FREEDOM-110,
FREEDOM-220
Data rates up to 9.6 kbps
Word format: software-configurable
Software
Terminal driven by software stored in each I/O module
CM-2 Management Interface
Functionality
Terminal management interface
SNMP agent with internal bridge/router and ARP server
for internal modules
Protocol conversion between internal management
protocols of I/O modules and external management
function
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com