Appendix D CM-2 Management Commands
Defining I/O Module Diagnostics
D-23
D.11
Defining I/O Module Diagnostics
Purpose
Enables/disables a test or diagnostic function to be performed on a selected I/O
module.
This command is relevant only for I/O modules that do not support direct
management by SNMP or by supervision terminal, for example ASMi-24,
ASMi-30, ASMi-31, ASMi-32, etc. For such modules, the CM-2 module provides
the terminal interface.
Format
NODE nn DEF TST
Procedure
➤
To enable/disable a test or diagnostic function:
• Type: NODE nn DEF TST
nn stands for the node number of the desired module, in the range of
1 through 12.
The first line of the data form appears. Use the general procedures to
define the parameter values, as required.
The contents of the form depend on the module type. Refer to the Installation and
Operation Manual of the corresponding module for detailed information.
MODEM DIAGNOSTIC
MODEM NAME: ASMI-31CQ(m)
DEFINE MODEM PORT NUMBER
: 1
MODEM STATUS
: MASTERE PERMANENT
SELECT MODEM
: MODEM 1 LOCAL
LOOP & BERT
: CANCEL
LOOP TIMEOUT
: N/A
REMOTE DIG ENABLE
: N/A
BERT RESULTS
: 0.0 E- 07
LED TEST
: OFF
LOCAL LOOP BACK
: N/A
REMOTE LOOP BACK
: N/A
REMOTE DIG
: N/A
ENABLE TEST FROM REM MODEM
: OFF
BERT ERR INJECTION
: N/A
Figure D-21. Modem Diagnostic Screen
Note