Lrs-24 with cm-2 module, Power-on, Normal indications – RAD Data comm LRS-24 User Manual
Page 8: Preliminary configuration
Quick Start Guide
LRS-24 Installation and Operation Manual
2
LRS-24 with CM-2 Module
2. LRS-24 with CM-2 Module
This section contains the startup instructions for LRS-24 with the CM-2 module.
Power-On
➤ To turn the power on:
1. Set the ON/OFF switches on the panels of the LRSI-PSP** modules to ON.
2. Supply the DC power, as applicable.
➤ To supply external phantom feed voltages:
1. Turn on LRS-24.
2. Turn on the source (for example, LRS-PS-FEED).
Normal Indications
• PS Module(s): All the indicators on the panel(s) of the PS module(s) must light
in green to indicate proper operation.
• CM-2 Module: The POWER indicator of the module must light. The TD and
RD indicators may flash (or light steadily) when a management session is in
progress.
Normally, the STAT/ADD display shows the two least significant digits of the
management number assigned to LRS-24. For normal startup, a rotating red circle
is displayed. However, if a problem is detected during the power-up self-test, you
will see a flashing error code (E1 through E9).
Preliminary Configuration
Perform preliminary configuration on the LRS-24 hub (see Chapter 4).