Table 4-2. Terminal Command Set Index for CM-2 Module (Cont.)
Command
Function/Action
DSP VER
Displays modem versions
DEF RST
Defines reset
DEF PWD
Define password
HLP
Displays list of commands supported by CM-2 module
4.4 Supervision Terminal Operating Instructions
General
This section provides procedures for using a supervision terminal to perform the
following activities:
• Preliminary configuration of the CM-2 module
• Preliminary configuration of I/O modules with internal SNMP agent
• Management of individual modules.
Before starting, make sure you are familiar with the configuration parameters and
management procedures of the CM-2 module, and of each module type installed
in LRS-24.
The procedures given in this section assume that no management station is actively
managing LRS-24. However, the same procedures also apply when the
management station relinquishes control to the supervision terminal.
Refer to the section Transferring Control to the Supervision Terminal below for an
explanation of the procedures used to transfer control from the management
station to the supervision terminal.
Configuring the Terminal
➤
To configure terminal for communication parameters used by the CM-2
Management RS-232 port:
1. Select the full-duplex mode and turn off the terminal echo.
The required communication parameters are 38.4 kbps, 1 start bit,
eight data bits, no parity, 1 stop bit, and no flow control.
2. Connect the supervision cable of the terminal to the MANAGEMENT RS-232
connector of the CM-2 module (refer to Section 4-2 for details).
3. Make sure LRS-24 is powered-up, and then turn on the supervision terminal.
When applicable, also turn on the modems and any other communication
equipment used to connect the terminal to LRS-24.
4. Start the configuration session.
5. Enter password.