3 operating the cm-1 supervision terminal, General, Configuring the terminal – RAD Data comm LRS-24 User Manual
Page 62
Chapter 3 Management via the CM-1 Module
LRS-24 Installation and Operation Manual
3-4
Operating the CM-1 Supervision Terminal
Management
RS-232
LRS-24
Supervision
Terminal
Modem
Modem
Telephone
Network
Figure 3-2. Typical Connection of Supervision Terminal Through Modem Link
3.3 Operating the CM-1 Supervision Terminal
General
This section provides general procedures for using a supervision terminal to
perform the preliminary configuration and to manage the individual CM-1
modules installed in LRS-24.
Before starting, make sure you are familiar with the configuration parameters and
management procedures of each module type installed in LRS-24, as described in
Installation and Operation Manuals for each module. The procedures given in this
section supplement the procedures appearing in these manuals.
To reconfigure or troubleshoot modules already configured, obtain the current
communication parameters and passwords from the system manager before
starting.
Configuring the Terminal
➤
To configure the terminal for communication parameters used by the module:
1. Select the full-duplex mode.
2. Turn off the terminal echo.
3. The recommended communication parameters are the default parameters:
9600 bps, 1 start bit, 8 data bits, odd parity, 1 stop bit, no flow control.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com