Chapter 3 Management via the CM-1 Module

LRS-24 Installation and Operation Manual

3-4

Operating the CM-1 Supervision Terminal

Management

RS-232

LRS-24

Supervision

Terminal

Modem

Modem

Telephone

Network

Figure 3-2. Typical Connection of Supervision Terminal Through Modem Link

3.3 Operating the CM-1 Supervision Terminal

General

This section provides general procedures for using a supervision terminal to

perform the preliminary configuration and to manage the individual CM-1
modules installed in LRS-24.
Before starting, make sure you are familiar with the configuration parameters and
management procedures of each module type installed in LRS-24, as described in
Installation and Operation Manuals for each module. The procedures given in this
section supplement the procedures appearing in these manuals.
To reconfigure or troubleshoot modules already configured, obtain the current
communication parameters and passwords from the system manager before
starting.

Configuring the Terminal

To configure the terminal for communication parameters used by the module:
1. Select the full-duplex mode.
2. Turn off the terminal echo.
3. The recommended communication parameters are the default parameters:

9600 bps, 1 start bit, 8 data bits, odd parity, 1 stop bit, no flow control.