Chapter 4 Management via the CM-2 Module
LRS-24 Installation and Operation Manual
4-14
Supervision Terminal Operating Instructions
Changing the Password
The factory set password is radlrs.
➤ To change the password:
1. Type NODE 13 DEF PWD
The Password Menu Screen appears (see Figure 4-5).
PASSWORD MENU
Enter new password
: radlrs
Enable password
: NO
Figure 4-5. Password Menu Screen
2. Type the new password (up to 27 characters, for terminal and TELNET).
3. If you forget the password, switch JP15 on CM-2 to BYPASS.
BYPASS PASSWORD
JP15
Figure 4-6. JP15 Settings
Preliminary Configuration
➤ To perform preliminary configuration:
1. Press the
which is by default CM2>.
2. Define the terminal type you are using by entering the command
NODE 13 DEF TRM
.
3. Use the command
NODE 13 DEF HUB
to define the parameters of the CM-2
module, and the general parameters of LRS-24 that you are configuring.
4. Use the command
NODE 13 DEF MNG
to define the management stations to
which to send traps generated by the CM-2 module.
5. Define the modem cards by entering
NODE 13 DEF CRD
to define the modules
installed in the LRS-24 hub.
Refer to Chapter 4 for detailed command syntax and protocol.
Configuring Individual Modules
After completing the preliminary configuration, begin configuration of the
individual I/O modules. Before starting this activity, it is recommended to use the
NODE 13 DSP HUB
command to identify the modules installed in LRS-24, since
configuration procedures depend on the module management type (IMOD or
SMOD), and model.