LRS-24 Installation and Operation Manual

4-14

Supervision Terminal Operating Instructions

Changing the Password

The factory set password is radlrs.

To change the password:

1. Type NODE 13 DEF PWD .

The Password Menu Screen appears (see Figure 4-5).

PASSWORD MENU

Enter new password

: radlrs

Enable password

: NO

Figure 4-5. Password Menu Screen

2. Type the new password (up to 27 characters, for terminal and TELNET).
3. If you forget the password, switch JP15 on CM-2 to BYPASS.

BYPASS PASSWORD

JP15

Figure 4-6. JP15 Settings

Preliminary Configuration

To perform preliminary configuration:

1. Press the key several times to see the working prompt of LRS-24,

which is by default CM2>.

2. Define the terminal type you are using by entering the command

NODE 13 DEF TRM

.

3. Use the command

NODE 13 DEF HUB

to define the parameters of the CM-2

module, and the general parameters of LRS-24 that you are configuring.

4. Use the command

NODE 13 DEF MNG

to define the management stations to

which to send traps generated by the CM-2 module.

5. Define the modem cards by entering

NODE 13 DEF CRD

to define the modules

installed in the LRS-24 hub.

Refer to Chapter 4 for detailed command syntax and protocol.

Configuring Individual Modules

After completing the preliminary configuration, begin configuration of the
individual I/O modules. Before starting this activity, it is recommended to use the
NODE 13 DSP HUB

command to identify the modules installed in LRS-24, since

configuration procedures depend on the module management type (IMOD or
SMOD), and model.