Connector wiring, Appendix a connector wiring, A.1 station clock interface – lrsi-f-cm1 module – RAD Data comm LRS-24 User Manual
Page 85
Station Clock Interface – LRSI-F-CM1 Module
A-1
Appendix A
Connector Wiring
This appendix provides connector information on:
• CM-1 module
• CM-2 module
• PS modules.
For information about the connectors located on the I/O (user) modules, and the
corresponding interface modules, refer to the corresponding Installation and
Operation Manual.
A.1 Station Clock Interface – LRSI-F-CM1 Module
The station clock interface located on the LRSI-F-CM1 module terminates in a
9-pin D-type female connector, designated STATION CLK, and wired in
accordance with Table A-1.
Table A-1. Pin Allocation for STATION CLK Connector
Pin
Function
1
Frame Ground
2, 3
Not Connected
4
Receive Clock Input (tip)
5
Receive Clock Input (ring)
6
Transmit Clock Output (tip)
7
Not Connected
8
Transmit Clock Output (ring)
9
Not Connected
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com