System Setup Utility B-3
Creating SSU Diskettes
SSU may be run directly from the E
XPRESS
B
UILDER
CD-ROM or from DOS-
bootable diskettes. Before you can run the SSU from diskettes, you must copy
the SSU from the E
XPRESS
B
UILDER
CD-ROM to a diskette.
If your diskette drive is disabled, or improperly configured, you must use the
FLASH-resident BIOS Setup Utility (
F2
) to enable it so that you can use the
SSU. If necessary, you can disable the drive after you exit the SSU. Information
entered using the SSU overrides information entered using Setup.
1.
Power on the system.
2.
If the diskette drive is disabled, enable it using the BIOS Setup Utility (see
Chapter 3, “Configuring Your System’). Specify the correct type of diskette
drive.
3.
Using the E
XPRESS
B
UILDER
CD-ROM, create the SSU diskette.
Note:
Ensure the diskettes do not contain any “bad
blocks”. Run CHKDSK or Format to check the quality of the
diskettes.
Running the SSU
Use the following steps to run the SSU.
1.
Power up your monitor and system.
2.
Start the SSU using one of the following methods.
T
After creating the three SSU diskettes from the CD:
Insert SSU diskette 1 into Drive A and reboot your server from the
diskette.
T
Directly from the Server Configuration CD:
Insert the configuration CD in your CD-ROM drive and reboot your
server from the CD. When prompted, press
F2
to enter BIOS Setup.
From the Boot menu, select Boot Device Priority and select CD-
ROM as your primary boot device
Save the settings and exit the BIOS Setup.
Reboot your server from the CD. The server displays a menu of
options.
3.
Follow the system prompts to load the SSU. When the SSU title appears on
the screen, press
Enter
to continue.
4.
The mouse driver loads, if available. Press
Enter
to continue.