Page 88 of 906

Circuit card installation

553-3001-211 Standard 3.00 August 2005

9

If there is an enable/disable switch, set it to Enb.

Note: Do not enable the switch on an NT8D04 Superloop Network card
or QPC414 Network card until network loop cables are installed.

10 If you are adding a voice, conference, or tone and digit loop, press the

manual initialize (Man Int) button on the NT5D03 or the NT5D10 Call
Processor if the card is associated with the active Call Processor:

Note: An initialization causes a momentary interruption in call
processing.

11 If you are installing the card in a working system, refer to the work order

and the Software Input/Output: Administration (553-3001-311) to add the
required office data to the system memory.

12 Go to the appropriate test procedure in “Acceptance tests” on

page 89

.