beautypg.com

Nt5d97 faceplate – Nortel Networks Circuit Card User Manual

Page 321

background image

NT5D97 Dual-port DTI2/PRI2 card

Page 321 of 906

Circuit Card

Description and Installation

Table 112 indicates how the RR control signal operates with regard to the
DDP2 status.

NT5D97 faceplate

Figure 65 on

page 322

illustrates the faceplate layout for the NT5D97 DDP

card. The faceplate contains an enable/disable switch; a DDCH status LED;
6 x 2 trunk port status LEDs; and six external connectors. Table 113 on

page 323

shows the name of each connector, its designation with respect to

the faceplate and the name and description of the card it is connected to. Also
shown are the names of the LEDs.

Table 112
DCH/MSDL Receiver Ready control signals

RR State

Condition

ON

D-Channel data rate selected at 64 Kbps

and

PRI2 loop is enabled

and

PRI2 link is not in OOS or Local Alarm mode state

and

PRI2 link is not transmitting a Remote Alarm pattern

and

PRI2 link is not receiving a Remote Alarm Indication
from a remote facility

OFF

All other conditions