beautypg.com

Power requirements, Foreign and surge voltage protections – Nortel Networks Circuit Card User Manual

Page 203

background image

NT5D11 and NT5D14 Lineside T1 Interface cards

Page 203 of 906

Circuit Card

Description and Installation

Power requirements

The lineside T1 card requires +15 V, –15 V, and +5 V from the backplane.
One NT8D06 IPE Power Supply AC or NT6D40 IPE Power Supply DC can
supply power to a maximum of eight lineside T1 cards. See Table 78.

Foreign and surge voltage protections

In-circuit protection against power line crosses or lightning is not provided on
the lineside T1 card. It does have protection against accidental shorts to –52 V
dc analog lines.

When the card is used to service off-premise terminal equipment through the
public telephone network, install a Channel Service Unit (CSU) as part of the
terminal equipment to provide external line protection.

Table 78
Lineside T1 card – power required

Voltage

Current (max.)

+ 5.0 V dc

1.6 Amp

+15.0 V dc

150 mA.

–15.0 V dc

150 mA.