Option settings

553-3001-211 Standard 3.00 August 2005

QPC43 Peripheral Signaling card

QPC71 E&M/DX Signaling and Paging Trunk cards

Options (minimum vintage N)

Plug location

NT5D21 Core/Network module

NT8D35 Network module

F13

Application

Unit 0 E35 switch

Unit 1 E5 switch

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

E&M

off

off

off

on

off

off

on

off

off

off

off

on

off

off

on

off

Paging

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

off

DX 2-wire
(conductor
loop <
2.5 K ¾)

on

on

off

off

off

on

off

on

on

on

off

off

off

on

off

on

DX 2-wire
(conductor
loop >
2.5 K ¾)

on

on

on

on

off

on

off

on

on

on

on

on

off

on

off

on

DX 4-wire
(conductor
loop <
2.5 K ¾)

off

off

off

off

on

on

off

on

off

off

off

off

on

on

off

on

DX 4-wire
(conductor
loop >
2.5 K ¾)

off

off

on

on

on

on

off

on

off

off

on

on

on

on

off

on

Note: DX trunks must be balanced correctly. If the loop is <2.5 K ¾, far-end balancing is
standard. If the loop is >2.5 K ¾, far end balancing requires standard plus 2.5 K ¾. To connect
PBX to PBX, switches should be arranged for loops to be >2.5 K ¾ at one end and <2.5 K ¾ at
the other. Apply similar treatment when connecting to Pulse QPJ69 trunks.