Option settings

553-3001-211 Standard 3.00 August 2005

QPC550 Direct Inward Dial Trunk card

Tables 52 through 56 give the option settings for the QPC550 DID Trunk
card.

Table 52
QPC550 vintages A and B—real/complex balance impedance selection

Device

location

Device

designation

Switch

number

Unit

number

Impedance type

Real

Complex

F31

S4.0

1

0

on

off

F24

S4.1

1

1

on

off

F16

S4.2

1

2

on

off

F11

S4.3

1

3

on

off

Table 53
QPC550 vintage A—600/900 Ohm impedance selection

Device

location

Device

designation

Unit

number

Impedance

(ohms)

Switch number

1

2

3

4

5

6

7

8

G29(a)

S3.0

0

600

off

on

on

off

off

on

on

off

900

on

off

off

on

on

off

off

on

G29(b)

S3.1

1

600

off

on

on

off

off

on

on

off

900

on

off

off

on

on

off

off

on

G8(a)

S3.2

2

600

off

on

on

off

off

on

on

off

900

on

off

off

on

on

off

off

on

G8(b)

S3.3

3

600

off

on

on

off

off

on

on

off

900

on

off

off

on

on

off

off

on