Circuit Card

Description and Installation

Note: If this feature is active, and the port is connected to a DTE that
holds DTR OFF when idle, the port will be permanently busied out to
inbound calls following the DTR timeout period.

Inactivity timeout

Once a successful data call is completed, the user's activity is monitored. If
no activity occurs within the amount of time configured in the downloaded
parameters, the DAC releases the call. Three minutes before the inactivity
timeout takes place, the DAC sends a warning message to the near-end
equipment if terminal mode is selected.

Wire test mode

The DAC allows for the EIA signaling leads to be tested to facilitate
installation and troubleshooting. This feature can be invoked through the
service change downloaded parameters, or by setting the appropriate front
panel switch. Wire test mode only operates when the port is idle. The leads
are cycled ON and OFF in 0.5 second periods (ON for 0.5 seconds, OFF for
0.5 seconds) for the number of cycles shown in Table 156 on

page 433

. The

lead status can be monitored by the front panel LEDs. The test will be run
indefinitely until the front panel switch is turned off, and the software wire
test parameters are disabled.

Note: For the most accurate results, be sure no equipment is connected
to the EIA leads.

Table 156
Wire test signal leads cycle counts

Label

EIA Signal Lead

description

Pin

Cycle count

RS-232-C

RS-422

TxD

Transmit

2

1

1

RxD

Receive

3

2

2

Note: The CTS signal is not included in the faceplate LED. Therefore, a
1.5-second delay will occur between the RxD lamp going on, and the DSR
lamp going on.