Configuring the ops analog line card, Jumper strap settings – Nortel Networks Circuit Card User Manual
Page 174

Page 174 of 906
NT1R20 Off-Premise Station Analog Line card
553-3001-211 Standard 3.00 August 2005
Configuring the OPS analog line card
The line type, terminating impedance, and balance network configuration for
each unit on the card is selected by software service change entries at the
system terminal and by jumper strap settings on the card.
Jumper strap settings
Each line interface unit on the card is equipped with two jumper blocks that
are used to select the proper loop current depending upon loop length. See
Table 71.
For units connected to loops of 460 to 2300 ohms, both jumper blocks for that
unit must have jumper blocks installed. For loops that are 460 ohms or less,
jumper blocks are not installed. Figure 24 on
shows the location of
the jumper blocks on the OPS analog line card.
Table 71
OPS analog line card – configuration (Part 1 of 2)
Application
On-premise station (ONS)
Off-premise station (OPS)
Class of Service
(CLS) (Note 1)
ONP
OPX
Loop resistance
(ohms)
0–460
0–2300 (Note 2)
Jumper strap
setting (Note 6)
Both JX.0 and JX.1
off
Both JX.0 and JX.1
off
Both JX.0 and JX.1
on
Loop loss (dB)
(Note 3)
0–1.5
>0–3.0
>2.5–3.0
0–1.5
>1.5–2.5
>2.5–4.5
>4.5–15
TIMP
(Notes 1, 4)
600
ohms
600
ohms
600
ohms
600
ohms
600
ohms
600
ohms
600
ohms
BIMP
(Notes 1, 4)
600
ohms
3COM
3CM2
600
ohms
3COM
3CM2
3CM2