6.1

Digital Trunk Unit (DTU–E1 CAS, CCS) - REX-BRD0002 or 2/ROFNB 157 13/1

Compliance to Regulations and Standards
The DTU–E1 provides 2 standard CEPT primary rate interfaces and meets the following
requirements:

CE regulation

: 91/263/EEC

CE marking

:

(this marking is not placed on the DTU–E1 board

because the DCT1900 system is already covered by the CE
marking of the cabinet)

Leased line CTR

: CTR12

G.703

: Electrical characteristics of the 2.048 Mbit/s synchronization

interface

G.704

: Synchronization frame structure at 2.048 Mbit/s

G.823

: Input jitter requirements

G.732

: Characteristics of primary rate PCM multiplex equipment

operating at 2.048 Mbit/s

I.431

: Primary rate layer 1

Environmental
Temperature

Operating

: 32 to 104

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications
Length x width

13.5" x 7.7" (343 x 195.6mm)

Digital Trunk Specification
Number of primary rate
interfaces per DTU board

: 2

Bit rate

: 2.048 Mbit/s

Signalling

: Common Channel Signalling (CCS), using firmware set

NTM/RYSNB 101 17/3

: Channel Associated Signalling (CAS), using firmware set

RYS 105 664