Nortel Networks DCT1900 User Manual
Page 126
Technical Product Manual - DCT1900
Configuration Directions, Base Station Powering
4-6
Config-DCT1900/R8/mw
© 2000-2005
Table 4–3 Power Consumption (Watts) of Base Stations and Cabling when Powered with 42V
26 AWG (0.4 mm) wire size (
∅)
24 AWG (0.5 mm) wire size (
∅)
22 AWG (0.64 mm) wire size (
∅)
Cable
length
(Feet)
1 pair
2 pairs
3 pairs
1 pair
2 pairs
3 pairs
1 pair
2 pairs
3 pairs
0
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
82
8.8
8.6
8.6
8.7
8.6
8.6
8.6
8.6
8.5
164
9.1
8.8
8.7
8.9
8.7
8.6
8.7
8.6
8.6
246
9.5
9.0
8.8
9.1
8.8
8.7
8.9
8.7
8.6
328
10.0
9.1
8.9
9.4
8.9
8.8
9.0
8.7
8.7
410
10.7
9.3
9.0
9.7
9.0
8.8
9.2
8.8
8.7
492
11.6
9.5
9.1
10.0
9.1
8.9
9.3
8.9
8.7
574
13.1
9.8
9.3
10.5
9.3
9.0
9.5
8.9
8.8
656
-
10.0
9.4
10.9
9.4
9.1
9.7
9.0
8.8
738
-
10.3
9.5
11.6
9.5
9.1
9.9
9.1
8.9
820
-
10.7
9.7
12.5
9.7
9.2
10.1
9.2
8.9
902
-
11.1
9.9
14.0
9.9
9.3
10.3
9.2
9.0
984
-
11.6
10.0
-
10.0
9.4
10.6
9.3
9.0
1066
-
12.2
10.2
-
10.2
9.5
10.9
9.4
9.1
1148
-
13.1
10.5
-
10.5
9.6
11.3
9.5
9.1
1230
-
14.7
10.7
-
10.7
9.7
11.7
9.6
9.2
1312
-
-
10.9
-
10.9
9.8
12.2
9.7
9.2
1476
-
-
11.6
-
11.6
10.0
14.0
9.9
9.3
1640
-
-
12.5
-
12.5
10.3
-
10.1
9.4
1804
-
-
14.0
-
14.0
10.6
-
10.3
9.5
1968
-
-
-
-
-
10.9
-
10.6
9.7
2132
-
-
-
-
-
11.3
-
10.9
9.8
2296
-
-
-
-
-
11.8
-
11.3
9.9
2460
-
-
-
-
-
12.5
-
11.7
10.1
2624
-
-
-
-
-
13.3
-
12.2
10.2
2788
-
-
-
-
-
15.0
-
12.9
10.4
2952
-
-
-
-
-
-
-
14.0
10.6
3116
-
-
-
-
-
-
-
-
10.8
3280
-
-
-
-
-
-
-
-
11.0
3444
-
-
-
-
-
-
-
-
11.3
3608
-
-
-
-
-
-
-
-
11.6
3772
-
-
-
-
-
-
-
-
11.9
3936
-
-
-
-
-
-
-
-
12.2
4100
-
-
-
-
-
-
-
-
12.7
4264
-
-
-
-
-
-
-
-
13.2
4428
-
-
-
-
-
-
-
-
14.0
4592
-
-
-
-
-
-
-
-
15.4