6.11

Line Termination Unit , LTU2 - REX-BRD0019A

Compliance to Regulations and Standards
EIA-470

: USA

Environmental
Temperature

Operating

: 32 to 158

°F (0 to 70°C)

Storage

: -40 to 158

°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications
Length x width

13.5" x 7.6" x .8" (344 x 192 x 20 mm)

Weight

.95 lb (430 grams) (excluding packaging)

Telephone Line Interface Specifications
Insulation

: 1.5 kVac between line and secondary circuitry
: 1 kVac between line and cabinet

DC Characteristics
Range of line current

: 60 mA max.

On–hook equivalent resistance : > 9 M between wires a and b for 200 Vdc
Resistance to earth (in quiescent
and loop state)

: 1 G between wires a/b and E-wire for up to 250 Vdc

AC Characteristics
On–hook impedance

: Software programmable 600 or complex

Off–hook impedance

: See ’Ringing Detection’

Return Loss

: 15 dB min.

Relative levels

: Software programmable

Input (AD loss) range

: 6 to -11dBr against 270 + (750 // 150 nF)

Output (DA loss) range

: 12 to -4.5 dBr against 270 + (750 // 150 nF)

Balancing impedance

: Software programmable; 600 , 900 or complex

Longitudinal conversion loss

: 60 dB min. between 50 Hz and 4 KHz

Ringing Detection
Ringing voltages

: 10 k min. between 24 to 90 Vrms, 25 to 50 Hz

Impedance for voice signals

: 100 k min. at AC voltages up to 2 V (peak),300 Hz to 3400 Hz

Capacity

: 1

μF +/- 5%

Ringing voltages

: 24 to 120 Vrms

Insensitive to signals

: 17 Vrms max.

Frequency range

: Software programmable between 16 and 64 Hz

Pulse Dialing
Make/break period

: Software programmable between 0 to 255 ms

Selected digit N generates

: N pulses and digit 0 generates either 10 pulses (default)

Line Voltage during pulsing

: Limited to 240 Vdc