Chapter 2, Base stations, 1 base station - krc 101 1371 – Nortel Networks DCT1900 User Manual
Page 65: 2base stations
Technical Product Manual - DCT1900
Product Specifications, Base Stations
Specs-DCT1900/R8/mw
2-1
© 2000-2005
C
HAPTER
2
Base Stations
2.1
Base Station - KRC 101 1371
**To order a complete Base Station, use Part Number: DB600-001**
Compliance to Regulations and Standards
PWT standard
: Parts 6,7,10
PWT(E) standard
: Interoperability standard
ANSI standard
: C63.17
UTAM standard
: LVP
Safety Standard
: UL60950
Emissions Standard
: FCC parts 15
Environmental
Temperature
Operating
: -31 to 169
°F (-35 to 76°C)
Storage
: -40 to 158
°F (-40 to 70°C)
Relative humidity
Operating
: 15 to 90%, non condensing
Storage
: 5 to 95%, non condensing
General Specifications
Powering method
: Centrally from the Radio Exchange, or using 48V external
power supply or a DC adapter
Size
: 7.875" x 6.5”"x 1.97" (200 x 165 x 50mm)
Weight
: 1lb. 2.5oz. (525g)
Material Cover
: ABS molded plastic
Color Cover
: light beige (NCS 1502–B)
Operating voltage
: 21 to 56 Vdc
Power Consumption
: maximum power consumption shall be less than 6W
Transmitter Radio Specifications
All specifications mentioned here are measured at the RF connectors located next to the
antennas.
RF carriers
Unlicensed:
Fc(MHz) = F2 - C x 1.25MHz, Where C = 0,1,2,3,4,5,6,7
F2 = 1.929375GHz
Frequency band
: 1850 to 1990 MHz
Center frequency stability
: "10 ppm (crystal controlled)
Modulation method
:
π/4 DQPSK
Power spectrum
:
π/4 DQPSK β/∝ = 0.5 RCC1
Peak output power at
RF–connector
: 3 to 19.5 dBm
Output Spurious
: as per ANSI C63.17 and ANSI C63.4
Harmonics
as per ANSI C63.17 and ANSI C63.4
Typical RF output impedance
: 50